Shrnutí obsahu

Strany 1 - Safety Mat System™

STTS Safety Mat System™ Soft Tactile Transducer Sensor Safety Mat System for Robotics and Hazardous Machinery Area Guarding Installation Manual

Strany 2

4 INSTALLATION WARNING: The entire machine safety system must be tested at the start of every shift. Machine testing should include: (1) proper

Strany 3

5 CONTROL SETUP Choose number of mat(s) per zone (metal box controller only): Zone 1 mats must start at Mat input #1 and work up. Zone 2 mats must

Strany 4 - Warranty

6 OPERATION GUIDE At power-up the control will go though a test and then, if manual reset option is enabled you must reset the zone. If automatic

Strany 5

7 JUMPER SETTINGS (metal box controller) Computer Board: S5 O O O O O O O O BOTTOM O O O O O O O O TOP

Strany 6 - TABLE OF CONTENTS

8 JUMPER SETTINGS (Din-Rail controller) 1= jumper install Number of Mats: JP2 JP1 0 0 1 mat 1 0 2 mats 0 1 3 mats 1

Strany 7 - SYSTEM OVERVIEW

9 ACCESSIBLE CONNECTIONS (Metal box controller) Computer board: J9 Diagnostics display plug J10 Connection to Power supply / Relay board J1

Strany 8

10 ACCESSIBLE CONNECTIONS (Din-Rail controller) Internal: J1 Diagnostics display plug (used by remote status display option) The Plug is loca

Strany 9

11 COMPUTER BOARD CONNECTOR / JUMPER LAYOUT Metal Box Controller J1-J8 MAT INPUT #1 thru #8 S5 MATS PER ZONE SELECTION J9 DIAGNOSTICS DISPLAY S1 F

Strany 10 - INSTALLATION

12 POWER SUPPLY BOARD CONNECTOR LAYOUT Metal Box Controller D2 +12VAC Supply K2 Safety Output D3 +5VAC Supply K3 Auxiliary Output D4 LED for the Fa

Strany 11 - Pittsburgh, PA 15233

13 BOARD CONNECTOR LAYOUT DIN-rail Controller J2,J26 MAT INPUT #1 thru #4 JP1,2 NUMBER OF MATS SELECTION J1 DIAGNOSTICS DISPLAY (remote) JP3 MANUAL

Strany 13

14 WIRING DIAGRAM FOR MAT(S) Metal Box Controller This example is for two mats. Each additional mat gets its own input (up to 8 on an input board

Strany 14

15 WIRING DIAGRAM FOR ZONE(S) (OUTPUTS) Metal Box Controller The following examples show two ways to wire a zone: Zone #1 is wired the standard me

Strany 15

16 WIRING DIAGRAM FOR MAT(S) DIN-rail Controller NOTE: Canadian market wiring is black, red, red, black with 18-guage wiring size. External

Strany 16

17 Remote Status Display NOTE: Canadian market wiring is black, red, red, black with 18-guage wiring size. NOTE: Terminal #6 (INPUT/OUTPUT

Strany 17 - Metal Box Controller

18 DIMENSIONS (Metal box controller) Dim "A" Dim "B" Dim "C" Dim "D" Dim "E" Dim "F"

Strany 18

19 DIMENSIONS (Din-Rail controller) The DIN-rail Controller can be either DIN-rail mounted or screwed down. Be sure to allow space for wiring to t

Strany 19 - DIN-rail Controller

20 DEVICENET SPECIFICATIONS Vendor ID code = 0459 Diagnostics Display: “OK U” DeviceNet unconnected (maybe unplugged from network) “OK C” Dev

Strany 20

21 DISPLAY CODES & MESSAGES CODE MESSAGE Description POSSIBLE CURE(S) 42-015/016R14 42-021/022R15 Occurs at power-up only Metal box Din-rail

Strany 21

22 DISPLAY CODES & MESSAGES (Continued) CODE MESSAGE POSSIBLE CAUSE(S) POSSIBLE CURE(S) 21 Zone 1 relay off, should be on Relay found in the

Strany 22 - WIRING DIAGRAM FOR MAT(S)

23 SAFETY EVALUATION Before releasing an installation for production, test the safety system on a daily basis or whenever a change or modification

Strany 23 - Remote Status Display

STTS Safety Mat System™ INSTALLATION MANUAL Pinnacle Systems, Inc. 3715 Swenson Avenue St. Charles, IL 60174 P/N: 28-023r2-0

Strany 24

24 MAINTENANCE WARNING: Read the entire maintenance section of the manual before any maintenance is attempted. The tasks which require definite t

Strany 25 - : 35 mm DIN-rail mountable

25 ANNEX A MAT SIZING AND LAYOUT (from #prEN999) The following formula is an international guideline for proper positioning and applicati

Strany 26 - DEVICENET SPECIFICATIONS

26 ANNEX B (informative) Walking speeds and stride lengths The positioning of equipment, which is activated by a person walking into the detection

Strany 27 - DISPLAY CODES & MESSAGES

27 ANNEX C (Installation Practices for Industry) The proper installation of the STTS Mat System is essential if the system is to operate properly.

Strany 28

28 2) All other system interconnect Cables. This includes serial interface cables, transducer cables, and unit power cables. 1.2) RACEWAY LAYOUT

Strany 29 - SAFETY EVALUATION

29 ANNEX D (Replacement Part Listing) Mat Wiring Part # Description E120 20’ Nano to Nano Extension E210 10’ Nano to Wire Extension E215 15’

Strany 31 - ANNEX A

31 WARRANTY Manufacturer warrants that this product will be free from defects in material and workmanship for a period of two years from the date o

Strany 32 - ANNEX B (informative)

32 Sales and Marketing Offices United States Pinnacle Systems, Inc. P.O. Box 100088 Pittsburgh, PA 15233 Toll Free Number: 800-569-7697 Di

Strany 33

i Proper Use and Limitations The information disclosed herein includes proprietary rights of the manufacturer. Neither this document nor the informa

Strany 34

ii LIMITATION OF LIABILITY In the event of any claim for breach of any obligations of manufacturer under any order, whether expressed or implied, and

Strany 35 - Replacement Relays

iii TABLE OF CONTENTS Proper Use and Limitations ...

Strany 36

1 SYSTEM OVERVIEW Together with a new patented mat technology, eliminating internal metal plates, and the STTS control using diverse redundant tech

Strany 37

2 TECHNICAL SPECIFICATIONS (Metal box controller) Power: 18 - 28VDC @ 18 Watts Optional, requires removal of transformer. (3 zones) 85-125V

Strany 38 - Sales and Marketing Offices

3 TECHNICAL SPECIFICATIONS (Din-Rail controller) Power: 24VDC +/- 15% @ 7 Watts maximum Fuse Rating: F1: 1A fuse Max # of Mats: Up to 4

Příbuzné modely Safety Mat Only (no controller)

Komentáře k této Příručce

Žádné komentáře